Hager Controls Bp 10140 Manual [exclusive] – Free Forever
The dial consists of 96 segments (tappets). Each segment represents 15 minutes.
Define the start date/time and the end date/time of your absence.
The switch usually has three positions: Manual ON, Automatic (watch symbol), and Manual OFF. Interface:
Installation must be performed by a qualified electrician in accordance with local national electrical codes and standards. DIN Rail Mounting
Connect the switched power wire for your device (e.g., light fixture or pump) to the Normally Open (NO) output (). hager controls bp 10140 manual
By following the guidelines in this article and consulting the official manual for your specific product, you can ensure a safe, reliable, and optimally configured Hager electrical installation.
Navigate to PROGRAM > MODIFY . Scroll through your saved steps, select the one you wish to change, adjust the parameters, and press OK .
: You can temporarily bypass the current program by using the front buttons to toggle the connected load manually. Essential Manual Steps
Rotate the minute dial clockwise until the aligns with the current time on the 24-hour dial. 2. Programming the On/Off Times The dial consists of 96 segments (tappets)
6. Where to Find the Official Hager Controls BP 10140 Manual
Product / Document reference
If the information in this guide does not resolve your issue or answer your question, refer to the manual specific to your device for the most accurate information. For further assistance, you can contact Hager directly at their France headquarters:
The switch contacts are on terminals 3 and 4 (or 4 and 5 depending on the exact variant/date of manufacture—always verify the diagram on the side of your unit). Typically, it is a single-pole, single-throw (SPST) dry contact. The switch usually has three positions: Manual ON,
Use shielded, twisted-pair cable for sensor connections, typically 18-22 AWG (0.5mm² - 0.75mm²) [1]. 4. Operational Modes and Programming
: Run your target output load line (e.g., lighting controls or blind motor relays) directly out from the secondary switch terminal point (typically marked as Pin 2). Programming & Operating Instructions Modifying System Time and Date