ПОЛУЧИТЕ ЕЩЕ -7% ПРИ ПОКУПКЕ ОНЛАЙН
Бесплатная доставка *

Wittmann Tempro Plus D 360 Manual Exclusive Jun 2026

To preserve operational reliability and prevent costly unplanned downtime, adhere strictly to the following maintenance timeline: Daily Inspections

When you power on the unit, the main screen displays the actual temperature (process value) and the set temperature (setpoint value) simultaneously. Visual indicators display current pump pressure, flow rate, and heating/cooling percentages. Adjusting the Temperature Setpoint Press the field on the touch display.

The incoming water pressure must be sufficient to supply the system before pressurization, typically requiring a minimum baseline pressure specified by Wittmann (often between 2 to 4 bar). 3. Piping and Hoses wittmann tempro plus d 360 manual exclusive

Displayed in GPM (gallons per minute) or LPM (liters per minute). A sudden drop indicates a restriction or kinked hose.

The target temperature for the mold.

Achieving operational excellence with this equipment requires a deep understanding of its technical parameters, safety protocols, and advanced control parameters. This comprehensive guide serves as an exclusive technical manual and optimization reference for process engineers and machine operators. 1. Technical Specifications and Architecture

The factory cooling water supply must have sufficient pressure differential relative to the unit's internal pressure to facilitate proper heat exchange. Electrical Integration The incoming water pressure must be sufficient to

: The exclusive manual details the correct startup sequence to prevent thermal shock and system cavitation. This includes opening the water supply, checking the fill level, powering on the main switch, and then using the touch-screen interface to set the pump speed and temperature setpoint. It emphasizes the importance of the automatic filling and constant pressure monitoring systems.

To understand what the D360 can do, it is helpful to see where it fits within the broader Tempro Plus D family. The table below summarizes the key models, providing a comparative context. A sudden drop indicates a restriction or kinked hose

This is often the most-thumbed section of the manual. The D 360 is equipped with a sophisticated self-diagnostic system. When a parameter drifts outside acceptable limits, the controller will display a specific error code on the touch screen.

Insufficient supply pressure to fill and pressurize the closed-loop system, or a major external leak.

Товар добавлен в корзину
Другие товары
У вас в корзине еще У вас в корзине еще товартоваратоваров