24V AC/DC, 115V AC, or 230V AC (model dependent). Output Signal: 0–20 mA or 4–20 mA analogue output.
The unit must be properly grounded to prevent electrical hazards. 3. Operating Instructions (OMD-11 Manual)
Often caused by a dirty measuring tube or air bubbles in the sample line. Ensure the sample flow is steady and the glass is clear. deckma omd11 manual
: Use mild dish soap or specialized oil solvent.
The is a definitive standard in marine environmental protection. As a high-performance Oil Content Meter (OCM), this 15 ppm bilge alarm system ensures compliance with stringent international maritime regulations. 24V AC/DC, 115V AC, or 230V AC (model dependent)
Ideally, the display panel should be at eye level with sufficient clearance on all sides for maintenance. Operation & Maintenance
Fix : Cycle the power supply off and on. Contact service if it persists. Meaning : Optical path is heavily blocked or fouled. : Use mild dish soap or specialized oil solvent
Pre-alarm triggers at 2.5 %/m. Main Alarm triggers at 5.0 %/m. (These values are adjustable but rarely changed due to class approval).
: Standard factory set point is 15 ppm, but it can be adjusted on-site to 5 ppm or 10 ppm via the front panel.
The measuring cell should be cleaned regularly using a dedicated bottle brush and mild detergent. A dirty glass tube is the most common cause of high ppm readings.
Here’s a helpful, practical review of the — based on common user feedback and technical documentation standards.