Merlin Gerin Multi 9 Ic 2000 P Manual Updated Now
Disclaimer: Electrical work is dangerous. Always isolate the supply and verify dead before touching terminals. When in doubt, call a licensed electrician.
Uses tunnel terminals for cables up to 6 mm² . It is critical not to run photocell cables (max 100m) in the same conduit as 230V power conductors to avoid interference.
A: No. The manual clearly states this unit is for “protection of equipment and fire prevention.” For people, you need a 30mA RCD.
Standard twilight operation relying on the sensor and Lux dial.
Complete Technical Guide and User Manual Insights for the Merlin Gerin Multi 9 IC 2000 P Twilight Switch
: Frequently described as a highly durable and resilient product. Users note it is "performant and reliable" for industrial or high-end residential use. Merlin Gerin Multi 9 Ic 2000 P Manual
Use the "Test" button to verify the relay clicks and the circuit triggers correctly. docs.rs-online.com For the full detailed manual, you can view the Acti 9- IC2000P+ Operating Instructions provided by Schneider Electric , the successor to the Merlin Gerin brand. Schneider Electric or a specific programming sequence for the 7-day schedule? light sensitive switches IC200, IC2000, IC2000P - RS Online 5 Jul 2001 —
Several reputable industrial libraries have archived the manual. Search for the part number (the internal reference for the 4P 63A 2000mA model). Reliable sites include:
What is the printed on the side of your unit (e.g., 15483, 16306)?
Use separate conduits for photocell cables and 230V AC power conductors to avoid interference. Maximum photocell cable length is 100 meters.
The wiring is straightforward, but must follow the diagram stamped on the side of the device: Disclaimer: Electrical work is dangerous
Bookmark the Schneider Electric obsolete document request page. It is the only official source for the authentic Merlin Gerin Multi 9 Ic 2000 P manual.
The device features an LCD display showing the current time, status, and programming options. 4.1. Initial Setup (Setting Time/Date) Rotate the dial to the Clock icon. Set the day of the week, hours, and minutes. Confirm settings. 4.2. Setting the Lux Level Rotate the dial to the Lux icon.
The IC 2000 P monitors outdoor light via a separate photoelectric cell (sensor). When light drops below a user-defined threshold, the switch activates connected lighting systems. Key Specifications 230V AC, 50/60 Hz Channel Capacity: 1 Output Channel Contact Rating: 16A resistive load (250V AC) Brightness Adjustment Range: 2 to 2000 Lux
Drop a comment below with your panel photo (or part number), and the community will help you out.
16A at 250V AC (cos phi = 1); 10A for inductive loads Uses tunnel terminals for cables up to 6 mm²
Observe the LED indicator. The LED will illuminate, and an audible "click" confirms the internal relay has closed, powering the lights.
Verify wiring (3-4 NO or 3-5 NC). Ensure mode is set to "AUTO". Wrong time/day set. Re-enter programming mode and verify times and days. Buttons not responding Device locked or error.
Allows for forced "ON" or "OFF" states, bypassing the automatic sensors. Holiday Mode:
While installing an RCD seems straightforward, the Multi 9 IC2000 P has specific nuances: